8333 SW Cirrus Dr
Beaverton, OR 97008
503-509-2026

Local Reviews
for forest grove, or


Job Locations
for forest grove, or

Anthony N.

Anthony N. Job Checkin

Commercial Diswasher Repair| unit won't not fill up automatically, checked and cleaned supply valve

Commercial Diswasher Repair| unit won't not fill up automatically, checked and cleaned supply valve

Aaron G.

Aaron G. Job Checkin

Commercial refrigeration repair. Walk in cooler repair.

Commercial refrigeration repair. Walk in cooler repair.

Herve Y.

Herve Y. Job Checkin

Heavy duty microwave ovens repair| Replacing blower and magnetrons, the microwave has successfully passed the test, and heat properly.

Heavy duty microwave ovens repair|
Replacing  blower  and magnetrons, the microwave has successfully passed the test, and heat properly.

Zach  T.

Zach T. Job Checkin

Diagnosing a walk-in cooler that is not reaching temperature.

Diagnosing a walk-in cooler that is not reaching temperature.

Herve Y.

Herve Y. Job Checkin

Turned the main breaker off - Opened the rear right service panel - Removed the heater element - Replaced the hi-limit switch and seal. The steamer is working fine after repair, generating good steam. However, I ve highly recommended to the customer to delime / descale the steamer very often, once a week. Also to install a water filtration system.

Turned the main breaker off - Opened the rear right service panel - Removed the heater element - Replaced the hi-limit switch and seal. The steamer is working fine after repair, generating good steam. However, I ve highly recommended to the customer to delime / descale the steamer very often, once a week. Also to install a water filtration system.

Zach  T.

Zach T. Job Checkin

Diagnosing an upright freezer that is not reaching temperature.

Diagnosing an upright freezer that is not reaching temperature.

Herve Y.

Herve Y. Job Checkin

COMMERCIAL REFRIGERATION REPAIR| the condenser fan motor is not working and needs to be replaced

COMMERCIAL REFRIGERATION REPAIR| the condenser fan motor is not working and needs to be replaced